Submitted by KevinS on Fri, 10/06/2022 - 21:20 Type Bug VRB 16-1-196 Priority Class 1 Status CLOSED Magnetic-Joint just does not work, whereas, miraculously it does for the Krones case. Comments AdamP corrected Cannot solve for internal mating when adjacent lines internal angle is less then 90 deg. Also added a Range factors for Homing and Running. These determine the size of the solve bracket = Roller radius * Rangefactor Fri, 24/06/2022 - 11:02 Permalink KevinS tested tested and added to help Mon, 11/07/2022 - 11:49 Permalink First Created Fri, 10/06/2022 - 12:00
AdamP corrected Cannot solve for internal mating when adjacent lines internal angle is less then 90 deg. Also added a Range factors for Homing and Running. These determine the size of the solve bracket = Roller radius * Rangefactor Fri, 24/06/2022 - 11:02 Permalink
Comments
corrected
Cannot solve for internal mating when adjacent lines internal angle is less then 90 deg.
Also added a Range factors for Homing and Running. These determine the size of the solve bracket = Roller radius * Rangefactor
tested
tested and added to help